This is considered an out of date browser. This website has been developed with modern browsers in mind to allow it to display at its best in a wide variety of viewing situations - including mobile viewing. But we haven't supported older browsers like IE8. Please upgrade to the latest version of Internet Explorer - or try Mozilla Firefox or Google Chrome. Both are excellent browsers.
Thank you.
The Kesternich Test is a common name for the corrosion test with sulfur dioxide under general moisture condensation. This test was developed in 1951 by Wilhelm Kesternich to simulate the damaging effects of acid rain.
Acid rain and acidic industrial pollutants are corrosive and can degrade coatings and plated surfaces. Kesternich testing, or sulfur dioxide testing, simulates acid rain or industrial chemical exposure to evaluate the relative corrosion resistance of the coating, substrate, or part itself. The test can be used for coatings or for base materials.
The test method is defined by various standards, DIN EN ISO 6988, DIN 50018, ASTM G87, ISO 3231, ISO 22479 are the most common. The parts to be tested are placed in a test chamber with a capacity of 300L and exposed to warm, moist air in combination with a certain amount of sulfur dioxide
Note: Sulfur is interchangeable with Sulphur and SO2 is the abbreviation for Sulfur/Sulphur Dioxide
The test chamber has a set volume of 300L. The construction of the inner housing of the chamber and the devices for arranging the samples must be made of inert and corrosion-resistant materials so that there is no reaction between the sample to be tested and the material of the chamber. The SO2 injection can be performed manually or automatically depending on the chamber.
The principle of the test is simple:
The test is usually carried out in cycles of 24 hours each.
Caution: The atmosphere containing sulfur dioxide must not be released into the room air.
Take samples from the chamber and let them dry in the room air. An initial assessment is made before any corrosion products are removed. When the tested parts are cleaned, the evaluation criteria must be taken into account.
Possible characteristics for evaluation: appearance after the test, appearance after removal of the corrosion products, number and size of imperfections, time to first corrosion, loss of mass. The results are described in a test report.
If you would like further information please call our experienced team on 01827 318040 or email sales@ascott-analytical.com